Pilot Operated Check Valves
Loading
English Chinese (Simplified)

comatrol hydraulic cartridge valves

 CP450-1 schematic

Pilot Operated Check Valve, Pilot to Open

Model No.
Cavity
Flow Pressure

RPC04

NCS04/3

20.5 lpm
[5.4 gpm]
350 bar
[5075 psi]

RPC06

NCS06/3

35 lpm
[9.3 gpm]
350 bar
[5075 psi]

CP450-1

SDC10-3

30 lpm
[8 gpm]
240 bar
[3480 psi]

RPC12

NCS12/3

90 lpm
[23.8 gpm]
315 bar
[4570 psi]

 CP451-2 schematic

Pilot Operated Check Valve, Reverse Pilot to Open

Model No.
Cavity
Flow Pressure

CP458-2

SDC08-3

20 lpm
[5 gpm]
210 bar
[3000 psi]

MC10-RO

SDC10-3S

45 lpm
[12 gpm]
250 bar
[3600 psi]

CP451-2

CP12-3S

95 lpm
[25 gpm]
210 bar
[3000 psi]

CP452-2

SDC16-3S

130 lpm
[34 gpm]
210 bar
[3000 psi]

CP453-2

CP20-3S

230 lpm
[61 gpm]
210 bar
[3000 psi]

 

RPV06 schematic 

Pilot Operated Check Valve, Pilot-to-open with drain

Model No.

Cavity

Flow Pressure

RPV 06

NCS06/4

30 lpm
[8 gpm]
315 bar
[4500 psi]

 CP453-5 schematic

Pilot Operated Check Valve, Reverse Pilot-to-open with vent

Model No.

Cavity

Flow Pressure

CP453-5

SDC20-2

250 lpm
[66 gpm]
350 bar
[5075 psi]

 

Pilot to Close

CP460-1 schematic

Pilot Operated Check Valve, Pilot to Close

Model No.
Cavity
Flow Pressure

CP460-1

SDC10-3

22 lpm
[5.8 gpm]
210 bar
[3000 psi]

CP461-1

CP12-3S

115 lpm
[30 gpm]
210 bar
[3000 psi]

CP462-1

SDC16-3S

190 lpm
[50 gpm]
210 bar
[3000 psi]

 

CP410-1 schematic

Dual Pilot-Operated Checks

Model No.
Cavity
Flow Pressure

CP410-1

none

85 lpm
[22 gpm]
210 bar
[3000 psi]